Maximum Storage. Maximum Confidence. Zero Diesel.
30kWp Solar · 30kVA Hybrid Inverter · 60kWh LiFePO₄ Battery · ₦22.9M
Ideal For
24/7 Lagos commercial operation — hospital, hotel, cold chain, or data room
24/7 operations — private security firms, data rooms, pharmaceutical cold storage
Large hotel or guesthouse where overnight AC failure means immediate guest complaints
Cold chain or food processing facility where refrigeration cannot tolerate interruption
High-footfall commercial site in a Band D/E area with unreliable grid and zero tolerance for downtime
Any business where the true cost of a power outage — lost inventory, SLA penalties, guest refunds — far exceeds the cost of this system
What This System Powers
6–8 units day and night
60kWh is the maximum battery configuration for the 30kVA inverter range — for sites where power continuity is non-negotiable.
Full commercial cold storage — uninterrupted, 24/7
Full property including emergency and exit lighting
All
50+ devices
3HP — yes
Industrial — yes
Confirm 3-phase loads and large motor starting currents with InfraSol engineer prior to installation.
Battery Autonomy
Overnight Scenario
60kWh at reduced overnight load (8–10kW: 2 ACs + cold storage + security) extends to 5.4–6.75 hours. Combined with typical Lagos grid windows (4–6hrs EKEDC supply), this delivers effective 24/7 power without a running generator.
System Specifications
| Solar Array | 30 kWp |
| Panel Brand | Jinko Solar Monocrystalline (Tier-1) |
| Inverter | 30 kVA Hybrid |
| Inverter Brands | Deye, SRNE |
| Battery Capacity | 60 kWh |
| Battery Chemistry | LiFePO₄ |
| Battery Cycle Life | 6,000–8,000 cycles (~15 year lifespan) |
| Usable Battery Capacity | 54 kWh |
| Daily Solar Generation | 129 kWh |
| Monthly Generation | 3870 kWh |
| Solar Utilisation | 78% |
| Monitoring | InfraSol real-time remote monitoring platform |
Financial Payback
Conservative (₦310/kWh blended avoided cost): customer in Band A/B area with 14–18hrs PHCN daily, moderate daytime loads. Base case (₦440/kWh): typical Band B/C Lagos customer, ~10hrs PHCN, 14hrs diesel, standard usage mix. Optimistic (₦490/kWh): Band C/D customer with heavy daytime operational loads and minimal grid supply. Diesel costed at ₦1,700/litre ÷ 2.6 kWh/litre practical gen efficiency = ₦654/kWh. Grid at ₦220/kWh (Band A reference rate). The more your consumption is concentrated during daylight hours, the faster the payback.
The Diesel Reality
A 30kVA generator running 16 hours daily burns 4,032 litres/month — ₦6.85M at ₦1,700/litre average. Add the generator capital replacement cycle (₦4–8M every 7 years), dedicated ops, and fuel shrinkage — and the true cost of diesel infrastructure at this scale is north of ₦8M/month. This system is the permanent answer.
Already on Band A?
Band A commercial customers still benefit significantly — solar eliminates diesel for daytime operations entirely, and the battery removes the most expensive grid peak hours.
Real-Time Remote Monitoring
Every InfraSol Commercial 30 Max includes InfraSol's real-time remote monitoring platform. Track solar generation, battery state-of-charge, grid usage, and system health from your phone — 24/7. Automated fault alerts and monthly energy intelligence reports included.
Learn more about our monitoringReady to eliminate your diesel costs?
Get a free site assessment and see exactly what the InfraSol Commercial 30 Max would save you every month.
Also available via Lease-to-Own (30–40% down, 3–5 months) or Uptime as a Service (flat monthly fee). View financing options