Solar for a Hotel, Supermarket or Private Hospital
48.4kWp Solar · 4 × SRNE 12kW hybrid · 120kWh LiFePO₄ · ₦44.8M, or from ₦37.2M




78 panels4 × 12kW4 × 30kWhTwo ways to buy this system
Both use the same inverters. The cheaper version has less battery and fewer panels, and you can add to it later without changing anything else.




64 panels4 × 12kW3 × 30kWh- 39.7 kWp of solar (64 panels)
- 90 kWh battery, about 6.8 hours at 12 kW overnight
- Payback 1.3–2.2 years
- Add 14 panels and a fourth 30kWh pack later.




78 panels4 × 12kW4 × 30kWh- 48.4 kWp of solar (78 panels)
- 120 kWh battery, about 9 hours at 12 kW overnight
- Payback 1.3–2.2 years
Installed prices for an outright purchase, as of October 2026. Product photos show the equipment used; the counts are on each picture.
Ideal For
Hotel, supermarket or private hospital running a 40–50kVA generator for most of the day
Hotel with 20–30 rooms, a kitchen and laundry
Supermarket with chillers, freezers and full lighting
Private hospital or clinic with theatres and a pharmacy cold chain
Office building with 50 or more staff
What This System Powers
12–15 units (1.5HP), or a mixed office load
Four inverters in parallel share the load.
Commercial cold storage around the clock
Full building lighting including outdoor and perimeter
All
Workstations, servers and building systems
Multiple pumps up to 3HP
Commercial laundry: yes, within the inverter rating
Three-phase motors. Four inverters cannot be split evenly across three phases, so this system is single-phase; use Business 36 or Business 72 on a three-phase site.
Battery Autonomy
Overnight Scenario
At a typical night-time load of 12kW (cold storage, security, corridors and occupied rooms), the 120kWh battery runs for about 9 hours. The cheaper version's 90kWh runs for about 6.8 hours.
System Specifications
| Solar Array | 48.4 kWp |
| Panels | 78 × Jinko Tiger Neo 620W N-type panel |
| Inverter | 48 kVA: 4 × SRNE 12kW hybrid |
| Phase | Single-phase |
| Battery Capacity | 120 kWh: 4 × Aurora 30kWh LiFePO₄ |
| Battery Chemistry | LiFePO₄ |
| Battery Cycle Life | 7-year warranty, over 6,000 cycles at 90% depth of discharge |
| Usable Battery Capacity | 108 kWh |
| Daily Solar Generation | 173.7 kWh |
| Monthly Generation | 5211 kWh |
| Solar Utilisation | 90% |
| Roof Space Needed | About 218 m² |
| Monitoring | InfraSol real-time remote monitoring platform |
Financial Payback
Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,310kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.
The Diesel Reality
A 50kVA generator running 14 hours a day burns roughly 2,460–3,720 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦4.7M–₦7.1M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. At this scale solar is a balance sheet decision as much as an energy one.
Already on Band A?
Band A businesses still benefit. The array carries daytime operations, when a business draws most of its power, and the battery covers outages and the evening tail instead of the generator. Charged from Band A mains, stored energy costs about ₦239/kWh against ₦640/kWh or more from diesel.
Real-Time Remote Monitoring
Every InfraSol Business 48 includes InfraSol's real-time remote monitoring platform. Track solar generation, battery state-of-charge, grid usage, and system health from your phone, 24/7. Automated fault alerts and monthly energy intelligence reports included.
Learn more about our monitoringReady to eliminate your diesel costs?
Get a free site assessment and see exactly what the InfraSol Business 48 would save you every month.
Also available via Lease-to-Own (30% down, then 3 monthly payments) or Energy as a Service (flat monthly fee). View financing options