Replace the 20kVA Generator That Runs Your Working Day
24.8kWp Solar · 2 × SRNE 12kW hybrid · 60kWh LiFePO₄ · ₦23M, or from ₦19.2M
Compare every 24kVA system and price



40 panels2 × 12kW2 × 30kWhTwo ways to buy this system
Both use the same inverters. The cheaper version has less battery and fewer panels, and you can add to it later without changing anything else.




32 panels2 × 12kW3 × 15kWh- 19.8 kWp of solar (32 panels)
- 45 kWh battery, about 6.8 hours at 6 kW overnight
- Payback 1.3–2.3 years
- Add 8 panels and a fourth 15kWh pack later (60kWh in total).




40 panels2 × 12kW2 × 30kWh- 24.8 kWp of solar (40 panels)
- 60 kWh battery, about 9 hours at 6 kW overnight
- Payback 1.3–2.2 years
Installed prices for an outright purchase, as of October 2026. Product photos show the equipment used; the counts are on each picture.
Ideal For
Office, clinic, pharmacy or restaurant currently running a 20kVA generator through the day
Office with 15–25 staff and 5–6 AC units
Clinic or diagnostics lab with an overnight cold chain
Restaurant or bakery with daytime cooking and cold rooms
Pharmacy or supermarket with chillers and lighting
What This System Powers
5–6 units (1.5HP) together in the day
Two inverters in parallel share the load; the array serves daytime cooling directly.
Display chillers, fridges and freezers around the clock
Full premises lighting
All
20–30 workstations, printers and network equipment
1–1.5HP pump: yes
Yes
Three-phase motors. Two inverters cannot be split evenly across three phases; choose Business 36 for a three-phase site.
Battery Autonomy
Overnight Scenario
At a typical night-time load of 6kW (chillers, CCTV, security lights and 1–2 ACs), the 60kWh battery runs for about 9 hours. The cheaper version's 45kWh runs for about 6.8 hours.
System Specifications
| Solar Array | 24.8 kWp |
| Panels | 40 × Jinko Tiger Neo 620W N-type panel |
| Inverter | 24 kVA: 2 × SRNE 12kW hybrid |
| Phase | Single-phase |
| Battery Capacity | 60 kWh: 2 × Aurora 30kWh LiFePO₄ |
| Battery Chemistry | LiFePO₄ |
| Battery Cycle Life | 7-year warranty, over 6,000 cycles at 90% depth of discharge |
| Usable Battery Capacity | 54 kWh |
| Daily Solar Generation | 89 kWh |
| Monthly Generation | 2670 kWh |
| Solar Utilisation | 90% |
| Roof Space Needed | About 112 m² |
| Monitoring | InfraSol real-time remote monitoring platform |
Financial Payback
Savings are the solar energy a system produces and the customer uses, valued at what that energy costs them today. Output is 1,310kWh per kWp a year, the Lagos figure for a well-oriented, unshaded array after system losses; we count 75% of it as used in homes and 90% in businesses, and give the battery no credit for charging from the grid, so the payback is conservative. Generator fuel is derived rather than assumed: litres/hour ≈ 0.25 × kW drawn + 0.037 × rated kVA, at ₦1,920/litre. The second term is fixed burn proportional to the set's size whether or not anything is plugged in, which is why an oversized generator costs more per kWh than one that is worked hard. Most Lagos generators run at 40–70% of rating; across that band fuel alone costs ₦607–₦702/kWh on a well-maintained engine, about ₦640/kWh at a typical 55% load, and around ₦800/kWh on a worn, lightly loaded one. Servicing, overhaul, managed-power premiums and diesel theft add another ₦60–₦120/kWh, which is what takes generator power past ₦700/kWh all-in. Band A grid is taken at ₦210/kWh. Conservative (₦366/kWh blended avoided cost): Band A home, 14–18 hours of mains, load weighted to the evening. Base case (₦531/kWh): Band B/C small business, roughly 10 hours of mains, mid-life generator. Optimistic (₦625/kWh): Band C/D commercial site with minimal grid and heavy daytime load. The more of your consumption falls in daylight hours, the faster the payback.
The Diesel Reality
A 20kVA generator running 12 hours a day burns roughly 840–1,270 litres of diesel a month, depending on how hard it is worked. At ₦1,920 a litre that is ₦1.6M–₦2.4M a month in fuel alone, before servicing, oil changes and the diesel that goes missing. Solar carries the working day, when a business uses most of its power.
Already on Band A?
Band A businesses still benefit. The array carries daytime operations, when a business draws most of its power, and the battery covers outages and the evening tail instead of the generator. Charged from Band A mains, stored energy costs about ₦239/kWh against ₦640/kWh or more from diesel.
Real-Time Remote Monitoring
Every InfraSol Business 24 includes InfraSol's real-time remote monitoring platform. Track solar generation, battery state-of-charge, grid usage, and system health from your phone, 24/7. Automated fault alerts and monthly energy intelligence reports included.
Learn more about our monitoringReady to eliminate your diesel costs?
Get a free site assessment and see exactly what the InfraSol Business 24 would save you every month.
Also available via Lease-to-Own (30% down, then 3 monthly payments) or Energy as a Service (flat monthly fee). View financing options