How Much Battery Per Air Conditioner? Solar Sizing for 1 to 8 ACs in Lagos

    The battery and panels each 1.5HP air conditioner adds, for homes that cool through the night and businesses that cool in the day, inverter and standard ACs alike.

    By InfraSol Research · 5 min readPublished 13 November 2026

    A wall-mounted hybrid inverter above lithium battery cabinets in a Lagos home
    Inverter and lithium batteries in a Lekki home.

    A 1.5HP inverter AC running all night needs about 13kWh of lithium battery to keep the generator off. The same AC running in office hours needs only about 6kWh, because the panels run it directly. That is the whole story of AC sizing in Lagos: when the AC runs matters more than how many you have.

    13 kWh vs 6 kWh

    Battery per 1.5HP inverter AC: running overnight at home vs in office hours. InfraSol Intelligence simulator, a full Lagos year with about 7 hours of grid a day.

    The rule of thumb

    • Home, ACs on from 8pm to 6am: each inverter AC adds about 13kWh of battery and 4 panels (2.4kWp) to the system.
    • Standard (non-inverter) ACs work too. They draw more while running, so each one adds about 19kWh of battery and 5 panels: about 46% more battery than an inverter AC. You don’t need to change your ACs to go solar.
    • Office, shop or school, ACs on from 8am to 6pm: each inverter AC adds only about 6kWh of battery but 6 panels (3.7kWp). A standard AC in the day adds about 8kWh and 8 panels.
    • Start from a base. The fridge, freezer, lights, TV and router need their own share: the 1-AC rows in the tables below include it.

    Homes: ACs on through the night

    At night there is no sun, so every hour of cooling comes out of the battery or the generator. A 1.5HP inverter AC averages about 1kW over a night as the compressor cycles, so 10 hours is about 10kWh. The battery has to hold that, plus the fridge and lights, plus a margin for the dull days when the panels don’t refill it, and it should never be run flat. That is why the answer is about 13kWh per AC, not 10.

    Smallest lithium battery and fewest Jinko 620W panels that keep a Lagos home's generator to under 60 litres a year (or under 3% of today's diesel), with 1.5HP ACs on from 8pm to 6am and about 7 hours of grid a day. InfraSol Intelligence simulator, 2026-11-13.
    ACsInverter ACs: batteryPanelsStandard ACs: batteryPanels
    1 AC20 kWh7 (4.3 kWp)25 kWh8 (5 kWp)
    2 ACs35 kWh10 (6.2 kWp)45 kWh13 (8.1 kWp)
    3 ACs45 kWh15 (9.3 kWp)60 kWh20 (12.4 kWp)
    4 ACs60 kWh17 (10.5 kWp)75 kWh25 (15.5 kWp)
    5 ACs70 kWh23 (14.3 kWp)100 kWh30 (18.6 kWp)
    6 ACs80 kWh27 (16.7 kWp)115 kWh36 (22.3 kWp)
    7 ACs100 kWh30 (18.6 kWp)140 kWh41 (25.4 kWp)
    8 ACs110 kWh34 (21.1 kWp)160 kWh46 (28.5 kWp)

    For a home with 3 inverter ACs, that takes the generator from about 2,427 litres of diesel a year to about 59. Our packages line up like this: 1 AC through the night is the 6kVA Max (15kWh) on a decent feeder, or a 10kVA Pro to keep the generator off on a poor one; 2 ACs is the 10kVA Pro or Max (30kWh); 4 ACs is the 20kVA Pro or Max; 6 to 8 ACs is the 30kVA to 50kVA.

    Businesses: ACs on in the day need far less battery

    An office AC runs while the sun is up, so the panels power it directly and the battery only covers clouds, the evening and the odd outage. Per AC, a home needs about 2.2 times as much battery as a business. For a daytime site the money goes into panels instead.

    The same test for an office, shop or school with 1.5HP ACs on from 8am to 6pm and about 7 hours of grid a day. InfraSol Intelligence simulator, 2026-11-13.
    ACsInverter ACs: batteryPanelsStandard ACs: batteryPanels
    1 AC10 kWh10 (6.2 kWp)10 kWh14 (8.7 kWp)
    2 ACs15 kWh17 (10.5 kWp)25 kWh19 (11.8 kWp)
    3 ACs25 kWh20 (12.4 kWp)35 kWh26 (16.1 kWp)
    4 ACs20 kWh33 (20.5 kWp)30 kWh41 (25.4 kWp)
    5 ACs30 kWh35 (21.7 kWp)50 kWh43 (26.7 kWp)
    6 ACs40 kWh38 (23.6 kWp)60 kWh51 (31.6 kWp)
    7 ACs50 kWh43 (26.7 kWp)65 kWh58 (36 kWp)
    8 ACs50 kWh52 (32.2 kWp)65 kWh71 (44 kWp)

    Read battery and panels together. From about 4 ACs, the cheapest way to keep a daytime generator off is more panels and slightly less battery, so the battery figure can dip as the panel count climbs. Both are what the simulator found cheapest at that size.

    What this means when you buy

    • Count the ACs you run at night, not the ACs you own. A home with 5 ACs that runs 2 overnight sizes its battery for 2.
    • The inverter size is set by how many ACs run at once. A 10kVA carries 2 to 3 together, a 20kVA 4 to 6. See the AC guide for what each size carries.
    • More grid means less battery. These figures assume a poor feeder giving about 7 hours a day, the safe side. On a good Band A feeder the grid refills the battery and you can start smaller and add batteries later.
    • Businesses: buy panels first. If your ACs run in the day, a bigger array does more for the diesel bill than a bigger battery.

    How we worked this out

    Every row is a full year, hour by hour (8,760 hours), in the InfraSol Intelligence simulator, using Lagos sun (1397kWh per kWp a year) and our measured 2026 grid pattern, set to about 7 hours of grid a day. For each number of ACs, the simulator tried every mix of 620W panels and lithium battery in 5kWh steps and kept the cheapest one that silences the generator: under 60 litres of diesel a year, or under 3% of what the same home or business burns today. The battery is used to 90% and charges from the grid when it falls below 30%, as most hybrid inverters are set. A 1.5HP inverter AC is taken as 1kW averaged over the hours it is on, and a standard AC as 1.4kW.

    Note: These are modelled figures for a typical load. Your ACs, room sizes, thermostat settings and feeder change the answer, so we size every quote from your own appliance list and your actual diesel and Eko bills. The 5kWh battery steps mean the odd row jumps more than its neighbours. Read the methodology for how the simulator works.

    Questions people ask

    Want these numbers for your own building?

    Tell us what you spend on diesel and NEPA each month and we’ll size the system, price it and show the payback.